TIANJIN CNPETRO HITECH CO.,LTD hitech@petrotape.com 86--15602138358
Product Details
Place of Origin: China
Brand Name: Heatshrink
Certification: ISO SGS
Model Number: Collar
Payment & Shipping Terms
Minimum Order Quantity: 500 sets
Price: Accordingly
Packaging Details: 37cmX37cmX47cm
Delivery Time: 10 days
Payment Terms: TT
Supply Ability: 1000Sets/Day
Impact Resistance: |
≥15J |
Designed For: |
Designed For The Corrosion Protection Of Pipeline Field Joints |
Low Temperature: |
-45 °C |
Installation: |
Rapid Installation Using Standard Propane Torches |
Key Word: |
Heat Shrink Culf |
DN: |
20''-45'' |
Thickness: |
1.5mm,2.5mm |
Adhesive Layer: |
High-performance Hot-melt Adhesive |
Impact Resistance: |
≥15J |
Designed For: |
Designed For The Corrosion Protection Of Pipeline Field Joints |
Low Temperature: |
-45 °C |
Installation: |
Rapid Installation Using Standard Propane Torches |
Key Word: |
Heat Shrink Culf |
DN: |
20''-45'' |
Thickness: |
1.5mm,2.5mm |
Adhesive Layer: |
High-performance Hot-melt Adhesive |
Russian Standard GOST R 51164-98 | PE Backing + Hot-Melt Adhesive | Field Joint & Weld Seam Corrosion Protection
Our Double-Layer Heat-Shrinkable Sleeves, Tapes, and Cuffs are a family of cold-to-warm applied corrosion protection products designed for field weld joints on steel pipelines, fully compliant with Russian Standard GOST R 51164-98 and related GOST requirements. The product range includes wraparound sleeves, continuous heat-shrinkable tapes, and pre-formed cuffs, all sharing a common two-layer construction: a radiation cross-linked polyethylene backing and a hot-melt adhesive layer.
These products are engineered for pipeline operators and contractors working in Russia, Central Asia, and other regions where GOST compliance is a mandatory project requirement. The double-layer construction provides reliable corrosion protection for operating temperatures up to 60°C (standard grade), with higher-temperature variants available for demanding service conditions.
| Product Form | Description | Typical Application |
|---|---|---|
| Heat-Shrinkable Sleeve | Wraparound sleeve with separate closure patch | Field joint corrosion protection on pipes with PE/PP factory coating |
| Heat-Shrinkable Tape | Continuous roll for spiral wrapping | Weld seams, irregular configurations, and repair areas |
| Heat-Shrinkable Cuff | Pre-formed tubular sleeve (no closure required) | Field joints where a seamless, closed configuration is preferred |
All three product forms share the same two-layer system construction and are qualified to the same GOST performance framework.
| Layer | Component | Function |
|---|---|---|
| Backing | Radiation cross-linked, thermally and light-stabilised polyethylene | Mechanical protection, moisture barrier, shrink memory, UV stability |
| Adhesive | Hot-melt adhesive (polymer-modified bitumen or equivalent) | Bonds to steel and compatible plant coatings; seals the joint against moisture ingress |
The backing is cross-linked by electron beam irradiation, providing the shrink force and thermal stability required for field application. The adhesive is formulated to flow under heat and form a continuous bond to the prepared steel and adjacent plant coating.
GOST R 51164-98 ("Steel main pipelines. General requirements for corrosion protection") is the primary Russian standard governing pipeline corrosion protection systems, including heat-shrinkable field joint coatings. The standard specifies requirements for:
Coating system performance and durability
Surface preparation requirements (Sa 2½ per GOST R ISO 8501-1 for heat-shrinkable tapes requiring preheat )4
Compatibility with cathodic protection systems
Quality control and acceptance criteria
Our double-layer heat-shrinkable products are manufactured and tested to meet the requirements of this standard, and are suitable for use in pipeline systems where GOST R 51164-98 compliance is specified.
| Standard | Scope |
|---|---|
| GOST R 51164-98 | General requirements for steel main pipeline corrosion protection |
| GOST 9.602 | Unified system of corrosion and ageing protection — underground structures |
| GOST R ISO 8501-1 | Surface preparation grades (Sa 2½ equivalent) |
Products in this family have been qualified to GOST requirements by manufacturers in the Russian market,Казахстан, Туркменистан, Узбекистан market, with documented approvals and compliance certificates available for project documentation
| Property | Typical Value | Reference |
|---|---|---|
| Backing Material | Radiation cross-linked PE | — |
| Adhesive Type | Hot-melt adhesive (polymer-modified bitumen or equivalent) | — |
| Backing Thickness | 0.5–0.8 mm (product-dependent) | — |
| Total Thickness | 1.2–2.4 mm (product-dependent) | — |
| Sleeve/Cuff Width | 450 mm (standard); customizable | — |
| Standard Operating Temperature | Up to 60°C | GOST R 51164-98 |
| Low Temperature Grades | -45°C / -25°C / -38°C (available on request) | — |
| Minimum Application Temperature | Per manufacturer's procedure (typically ≥ +5°C ambient) | — |
| Surface Preparation | Sa 2½ per GOST R ISO 8501-1 (for preheat-required systems) | |
| Peel Strength | Per GOST R 51164-98 requirements | — |
| Cathodic Disbondment | Per GOST R 51164-98 requirements | — |
| Dielectric Strength | ≥ 15 kV/mm | — |
Values are indicative and shall be confirmed against the specific product data sheet and GOST qualification test reports.
| Feature | Benefit |
|---|---|
| GOST R 51164-98 Compliant | Meets Russian regulatory requirements for pipeline corrosion protection |
| Double-Layer Construction | PE backing + hot-melt adhesive; reliable, field-proven system |
| Multiple Product Forms | Sleeves, tapes, and cuffs available to suit different joint configurations and application preferences |
| Radiation Cross-Linked Backing | Durable, UV-stabilised, and resistant to mechanical damage and environmental degradation |
| Hot-Melt Adhesive | Bonds to steel and compatible plant coatings (PE, PP, FBE, bitumen) |
| Cathodic Protection Compatible | Does not shield CP current; suitable for pipelines with electrochemical protection |
| Complete System Available | Can be supplied with epoxy primer, closure patch (for sleeves), and installation accessories |
| Scenario | Suitability |
|---|---|
| Russian and CIS pipeline projects | Where GOST R 51164-98 compliance is mandatory |
| Field joint corrosion protection | Girth welds on PE/PP-coated steel pipelines |
| Weld seam and repair areas | Heat-shrinkable tape for irregular configurations |
| Operating temperatures up to 60°C | Standard grade; higher grades available for elevated service |
| Buried and above-ground pipelines | Onshore transmission and gathering lines |
| Pipeline rehabilitation | Restoration of damaged field joint coatings |
| Item | Details |
|---|---|
| Heat-Shrinkable Sleeve | Wraparound configuration with closure patch |
| Heat-Shrinkable Tape | Continuous roll for spiral wrapping |
| Heat-Shrinkable Cuff | Pre-formed tubular sleeve |
| Epoxy Primer (optional) | Two-component, for three-layer system where specified |
| Documentation | TDS, MSDS, GOST compliance certificates, installation procedure, traceability records |
Surface Preparation: Clean the steel cutback to Sa 2½ per GOST R ISO 8501-1 (for systems requiring preheat) . Remove dust, oil, and contaminants.
Preheat: Preheat the steel surface to the manufacturer's recommended temperature.
Apply Primer (if specified): Apply two-component epoxy primer to the steel only.
Position Product: Wrap the sleeve or tape around the joint, or slide the cuff into position. For sleeves, secure the closure patch.
Shrink: Apply heat uniformly with a propane torch, working from the center outward, until the backing shrinks and adhesive flows at the edges.
Inspect: Verify complete shrinkage, adhesive flow, and absence of voids or lifted edges.
CNPetro — Protecting pipelines. Advancing performance.
For product data sheets, GOST R 51164-98 compliance documentation, or project-specific technical consultation, please contact our sales team.
Keywords: double-layer heat-shrinkable sleeve, heat-shrinkable tape, heat-shrinkable cuff, GOST R 51164-98, Russian standard, pipeline corrosion protection, PE backing, hot-melt adhesive, field joint coating